Frequently asked questions about support surfaces

The National Pressure Ulcer Advisory Panel (NPUAP) describes support surfaces as “specialized devices for pressure redistribution designed for management of tissue loads, microclimate, and/or other therapeutic functions.” These devices include specialized mattresses, mattress overlays, chair cushions, and pads used on transport stretchers, operating room (OR) tables, examination or procedure tables, and gurneys. Some support surfaces are part of an integrated bed system, which combines the bed frame and support surface into a single unit.

Support surfaces must be used in conjunction with other interventions, such as nutritional support, skin care, repositioning, pressure redistribution, risk identification, and patient and caregiver education. Although studies have shown that support surfaces can help decrease the incidence of pressure injuries (PIs), there is no evidence showing one brand or type of support surface is better than another.

What does it mean when a support surface is described as reactive or active?

Reactive surfaces, also called reactive/continuous low pressure, may be powered or not powered and can adjust pressure redistribution only when a load (such as the weight of a patient) is applied to it.

An active surface is always powered. Pressure distribution is adjusted mechanically, even when there is no patient on the surface.

What materials are used in support surfaces?

Materials include foam, gel, fluid, and silicone beads. Australian medical-grade sheepskin is also used, but has limited availability in the United States. Some support surfaces have covers made of Gore-Tex® or another material that helps reduce friction.

What do the terms immersion, envelopment, and bottoming out mean?

Pressure redistribution with support surfaces is achieved through immersion and envelopment.

Immersion refers to the fact that as the body sinks into the surface, pressure is redistributed over the entire area of contact and not just the bony prominences. Envelopment is the ability of the support surface to conform evenly to irregularities, such as body contours, linens, and the patient’s clothing, without causing excessive pressure on the body.

Bottoming out refers to the patient’s body sinking in so deeply on the support surface that it rests against the bed frame or another surface, such as a gurney, that lacks sufficient cushioning.

What is microclimate control?

Microclimate control (control of temperature and moisture) is achieved by:

controlling the airflow against the skin by pumping air through minute perforations in the surface cover

increasing the exchange of air between the skin and the surface through the use of porous covers that allow moisture evaporation and body heat dissipation.

This feature keeps the skin cool and dry.

Microclimate control is beneficial for patients who are constantly moist (for example, diaphoretic or incontinent). Excess moisture raises the risk of friction and shear, which can result in skin breakdown. The coolness feature helps avoid higher skin temperature, a risk factor for PIs.

What do the features lateral rotation, alternating pressure, low air loss, and air fluidized mean?

These features are the functional or therapeutic components of a support surface. They can be used singly or in combination.

With continuous lateral rotation, or simply lateral rotation, the surface provides rotation longitudinally (head-to-toe), turning the patient to a set degree, in a set duration, and at a set frequency. Rotation is limited to 40 degrees or less to each side. Lateral rotation does not replace repositioning the patient to address skin issues, nor does it provide pressure redistribution or offloading. Instead, surfaces with this feature help facilitate pulmonary hygiene among patients with acute respiratory conditions.

NPUAP defines alternating pressure as “a feature of a support surface that provides pressure redistribution via cyclic changes in loading and unloading as characterized by frequency, duration, amplitude, and rate of change parameters.” Surfaces with alternating pressure may be mattresses or overlays and are always powered. They can change distribution of load with or without applied load—even when no patient is in the bed. These surfaces have air cells that cyclically inflate and deflate, thus changing the areas of the body under pressure.

Low air loss means that the surface provides flow of air to help manage the microclimate of the patient’s skin.

Air-fluidized surfaces provide pressure redistribution by immersion and envelopment, using a fluid-like medium created by forcing air through silicone beads. Air-fluidized surfaces are expensive and difficult to maintain; beds with these surfaces are usually rented instead of purchased. They are heavier than a standard bed, so are not always suitable to place in older homes.

Air-fluidized beds are often used for patients with multiple full-thickness wounds or who have undergone myocutaneous procedures. They are not typically recommended for a patient with an unstable spine or pulmonary disease. The fluid-like surface doesn’t provide sufficient support for a patient with an unstable spine, and for patients with pulmonary disease, the lack of firm support makes it difficult for patients to cough effectively.

What are general considerations for matching patients to appropriate support surfaces?

It’s important to base the choice of support surface on individual patient needs. (See Determining type of support surface.) For example, consider the patient’s weight, height, and shape. (Bariatric patients must use bariatric surfaces; be aware of the weight limitation of the surfaces.)

Other considerations include:

risk for new PIs

number of current PIs, including severity and location

patient’s activity, mobility (for example, avoid surfaces that might make it difficult to get a patient out of bed), and moisture

risk for falls and entrapment in the bed

appropriateness for the setting (for example, powered surfaces can’t be used in a home without a reliable power source).

Consider contraindications when choosing a support surface. For example, reactive/constant low pressure, reactive/constant low pressure with low air loss, active surfaces with alternating pressure feature, and air-fluidized surfaces are contraindicated for patients with unstable cervical, thoracic, and lumbar spines, and patients with cervical or skeletal traction.

Assess the appropriateness of the choice on a regular basis. For example, a patient with multiple stage 3 PIs that have healed may no longer need the surface with low air loss but can now be placed on a reactive/ constant low pressure surface. If a patient experiences pain or discomfort with a particular surface, consider alternatives.

What are important points to remember when using support surfaces?

Education is key to promote optimal use of these surfaces. Staff such as nurses, certified nursing assistants, and other team members who handle the surfaces, including housekeeping and maintenance staff, all need information on how to use the support surface correctly. Education should extend to families, caregivers, and patients in the home setting.

Although the manufacturer may state an expected lifespan for a product, staff must be taught that the lifespan can be shorter, depending on use. Staff need to be aware of indicators of wear and tear; discoloration; any change in height or thickness of the surface; any break in the seams, cover, zippers, flaps; breakdown of internal components; or presence of foul odor. Deficient products must be repaired or replaced.

Other important points related to using support surfaces include the following:

Ensure the appropriate type and number of linens or liners are used with the surfaces. For example, a liner with a plastic bottom is not ideal with low air loss surfaces because the non-breathable feature of the plastic will not allow the air from the support surface to go through.

Clean surfaces as specified by the manufacturers. If the correct cleaning process is not used, the surface poses an infection risk. Incorrect use of agents, for example using products that destroy the integrity of the cover, also increases the risk of cross-infection.

Most importantly, remember that patients must still be repositioned even if they are in a support surface. An active support surface should be used when frequent manual repositioning is not possible. When possible, avoid positioning a patient with an existing PI on the affected area.

What should facilities use as support surfaces in the OR, ED, and procedure areas?

Support surface options for the OR include air, gel, and high-specification foam mattresses. Consider the patient position required for the procedure when making a selection. There are also pads with pressure redistribution properties that can be used for transport and on ED beds. More research is needed to determine the effectiveness and proper use of these support surfaces. When selecting products to use in these special situations, consider safety, care, and costs.

Understanding support surfaces

Support surfaces are an integral part of PI prevention and treatment. When selecting a surface, the patient’s individual needs, including past experiences with the surfaces, must be taken into consideration. It’s important for clinicians to continuously assess patients for the appropriateness and the functionality of the surface.

Armi S. Earlam is the lead certified wound, ostomy, and continence nurse at Lutheran Medical Center in Wheat Ridge, Colorado.

Selected references

Centers for Medicare and Medicaid Services. National Coverage Determination (NCD) for air-fluidized bed (280.8).

Mackey D, Watts C. Therapeutic surfaces for bed and chair. In Doughty D, McNichol L, eds. Core Curriculum: Wound Management. Philadelphia, PA: Wolster Klower; 2016:362-83.

McNichol L, Watts C, Mackey D, et al. Identifying the right surface for the right patient at the right time: generation and content validation of an algorithm for support surface selection. J Wound Ostomy Continence Nurs. 2015;42(1):19-37.

Moore Z, Stephen Haynes J, Callaghan R. Prevention and management of pressure ulcers: support surfaces. Br J Nurs. 2014;23(6):S36-S43.

National Pressure Advisory Panel. Terms and definitions related to support surfaces. 2007.

National Pressure Ulcer Advisory Panel, European Pressure Ulcer Advisory Panel, & Pan Pacific Pressure Injury Alliance. Prevention and treatment of pressure ulcers: clinical practice guidelines. Osborne Park, Australia: Cambridge Media; 2014.

FAQs about support surfaces

Support surfaces are consistently recommended for the prevention and treatment of pressure ulcers. So patients can derive optimal benefits from support surfaces, clinicians must understand how to use them effectively. This article answers several questions about these useful tools.

What is a support surface?

The National Pressure Ulcer Advisory Panel (NPUAP) defines support surfaces as “specialized devices for pressure redistribution designed for the management of tissue loads, microclimate, and/or other therapeutic functions (i.e., any mattress, integrated bed system, mattress replacement, overlay, seat cushion, or seat cushion overlay)”.

Support surfaces are designed to redistribute pressure on skin, tissue, and bony prominences. The redistribution of pressure (“load”) is achieved by the design of the support surface.

Examples of support surface devices for a sleeping surface include mattress replacement systems, overlays that fit on top of a standard mattress, and specialized mattresses. Examples of support surface

devices for a seated surface include specialized seat or wheelchair cushions and overlays. Support surfaces may be constructed of different materials or combination of materials, such as foam products, air, gel, or liquid.

What are some features of support surfaces?

Support surfaces fall into one of two categories:

Reactive support surfaces provide redistribution by immersion and envelopment. In other words, they conform to a person’s body shape, which decreases the pressure over bony prominences.

Active support surfaces shift the contact over the skin and tissue against the support surface periodically or at set intervals.

Individual support surfaces may have additional features. For example, a reactive support surface with a low-air-loss feature provides not only immersion and envelopment but also changes the microclimate (the temperature and humidity of the patient) by increasing evaporation and heat transfer from the patient’s skin.

A feature of some active support surfaces is alternating pressure, which changes load periodically: The powered active support surface changes the pressure on a specific area of the body by alternating higher and lower pressures.

How are support surfaces best used?

The 2014 Prevention and Treatment of Pressure Ulcers: Clinical Practice Guideline, from NPUAP, European Pressure Ulcer Advisory Panel, and Pan Pacific Pressure Injury Alliance contains several recommendations related to the use of support surfaces. These guidelines form the basis for how to manage support surfaces.

Choose a support surface that meets the person’s needs

Factors to consider include the individual’s activity, mobility, size, weight, risk for (and existing) pressure ulcers, and the need for microclimate control and sheer reduction. For example, a mattress must properly fit the bed frame. If the mattress is too narrow, the patient could become entrapped.

Match the support surface to the care setting. For example, space, ventilation, door width, and ability to use a continuous power source should be considered.

Conduct assessments on a regular basis

Support surfaces require ongoing assessment and monitoring:

Assess the function of the support surface when it’s initiated and each time you interact with a patient, just as you would check an infusion pump. For instance, the electrical plug for a powered support surface may have been knocked out of the socket or the setting could have been changed for transfers from the bed to the chair and not changed back.

Remember that support surfaces have a finite functional life span, meaning they do not continue providing the expected pressure redistribution for an unlimited period of time. Follow the manufacturer’s guidelines regarding testing function.

Choose materials compatible with the support surface

Choose clothing, linens, and incontinence pads that are compatible with the support surface. For instance, specially made disposable incontinence pads will allow air movement, which maximizes the benefit of a low-air-loss mattress.

In addition, limit the number of linens and incontinence pads on support surfaces. Studies show that excess linens and incontinence pads interfere with support surface therapy. For example, Williamson and others found that multiple layers of linens and pads increased the interface pressure between the skin and the top of the mattress. In another study, Williams and others found that each additional layer of linens and/or pads on a low-air-loss support surface reduced the surface’s ability to manage moisture-vapor transmission, which leads to decreased effectiveness.

Continue to reposition the patient

The patient must be turned and repositioned, unless this is contraindicated by a medical condition. Individualized treatment

plan and turning schedules should be developed based upon the patient’s general condition related to skin and comfort measures. The care plan should reflect the turning and repositioning schedule and a rationale if the schedule deviates from standard policy.

Consider unique needs based on the support surface

Some support surfaces present circumstances that require special patient care. For example, dehydration may occur with some bed systems that are warmer and have a more intense airflow. When using this equipment, the patient’s fluid intake may need to be increased.

How can I promote optimal use of support surfaces?

Staff education is an integral element for providing appropriate support surface therapy. Education should include all staff members who care for the individual or the equipment. Assess the staff’s knowledge before developing an educational plan, so it can be tailored to their specific needs. After education, reassess to verify staff’s understanding. (See Suggested topics for a support-surfaces education program.)

Through better understanding of support surface therapy and its appropriate use, you can help provide patients with quality, cost-effective care. ?

Tony Forsberg is senior account executive and Rosalyn S. Jordan is clinical director of postacute clinical programs and services for Joerns Health Care in Charlotte, North Carolina.

Selected references

ANSI/RESNA. SS-1 Support Surfaces. Section 1 Vocabulary. Arlington, VA: Rehabilitation Engineering and Assistive Technology Society of North America; 2014.b Call E, Deppisch M, Jordan R, et al. Hand Check Method: Is it an Effective Method to Monitor for Bottoming Out? A National Pressure Ulcer Advisory Position Statement; 2015. www.npuap.org.

McNichol L, Watts C, Mackey D, et al. Identifying the right surface for the right patient at the right time: generation and content validation of an algorithm for support surface selection. J Wound, Ostomy, Continence Nurs. 2015;42(1):19-37.

National Pressure Ulcer Advisory Panel, European Pressure Ulcer Advisory Panel and Pan Pacific Pressure Injury Alliance. Emily Haesler (Ed). Prevention and Treatment of Pressure Ulcers: Clinical Practice Guideline. Cambridge Media: Osborne Park, Western Australia; 2014.

Stone A, Brienza D, Call E, et al. Standardizing support surface testing and reporting; A National Pressure Ulcer Advisory Panel Executive Summary. Wound, Ostomy, Continence Nurs. 2015;42(5):445-49.

Williamson R, Lachenbruch C, VanGilder C. A laboratory study examining the impact of linen use on low-air-loss support surface heat and water vapor transmission rates. Ostomy Wound Manage. 2013;59(8):32-41.

Williamson R, Lachenbruch C, VanGilder C, et al. The effect of multiple layers of linens on surface interface pressure: results of a laboratory study. Ostomy Wound Manage. 2013;59(6):38-47.

Resources

Download a table of support surface terms and definitions from the National Pressure Ulcer Advisory Panel Support Surface Standards Initiative.

Download a quick reference guide for the 2014 Prevention and Treatment of Pressure Ulcers: Clinical Practice Guideline.